OSHA White PaperLab Sample ID: 2329156003 — October 14, 2023

iQMS362 16.5" Masonry Saw (Predecessor to iQMS362i)
Independent Silica Dust Testing

Total Silica: 4.9 ug/m³
<0.25 μg/m³ over 8hr TWA

Test Overview

Cutting Equipment

iQMS362 electric masonry 16.5" saw for materials up to 5.5" high, 24" wide and 24" long

Dust Collection

iQMS362 16.5" masonry saw with integrated vacuum, filter and dust containment system

Materials

Manufactured Concrete Paver 4"x8" and Standard Red Face Brick

Number of Cuts

100 thru cuts of red brick + 100 thru cuts of concrete paver

Air Sampling Duration

480 minutes in operator's breathing zone

Testing Laboratory

ALS Global Environmental Laboratory, Salt Lake City UT 84123

Test Documentation

iQMS362 OSHA Silica Dust Testing White Paper

Analytical Results

MS362 Sample C — In Person (Breathing Zone)

Lab ID: 2329156001 · Collected: 10/14/2023 · iQ Power Tools, Perris

PASS

NIOSH 0600 — Respirable Dust

mg/sample

0.083

mg/m³

0.069

Reporting Limit

0.020

NIOSH 7500 — Crystalline Silica

AnalyteResult (ug/m³)Result (%)
Quartz5.94.9 / 7.1%
Cristobalite<4.2<6.0
Tridymite<17<24
Total Silica5.9 (4.9 ug/m³)7.1%

Understanding the Results in Context

The original iQMS362 recorded Total Silica at 4.9 ug/m³ — just 9.8% of OSHA's PEL (50 ug/m³) and 19.6% of the Action Level (25 ug/m³). The current iQMS362i (tested separately) achieved Total Silica ND, reflecting further engineering improvements.

Monitoring and Analysis Methods

Air samples were collected at iQ Power Tools, 4635 Wade Avenue, Perris, CA, 92571 during dry cutting activities. Samples used SKC Brand of AirCheck Touch air sampling pumps on pre-weighted 3-piece matched weight 37 mm PVC filter media and SKC GS-3 plastic cyclones (SKC Part #225-100) at a flow rate of 2.75 liters per minute (LPM). Analysis was conducted at an AIHA accredited laboratory, ALS Laboratory in Salt Lake City, Utah, in accordance with current OSHA regulations using NIOSH method 0600 and method 7500.

Result: Total Silica 4.9 ug/m³

The predecessor iQMS362 kept silica exposure 90% below OSHA's PEL — fully OSHA Table 1 compliant. The updated iQMS362i improved this further to Total Silica Not Detected.

Disclaimer: iQ Power Tools dry-cut masonry saws are not specifically listed under OSHA Table 1. However, independent air monitoring conducted by ALS Global Environmental Laboratory demonstrates operator respirable crystalline silica exposures substantially below OSHA's 50 µg/m³ Permissible Exposure Limit when the saws are operated with their integrated dust collection systems as intended. Therefore, employers may use the objective data and exposure assessment provisions of OSHA 29 CFR 1926.1153 to support silica compliance. Results may vary based on material type, cutting conditions, and equipment maintenance.